Free DIY appliance repair guides since 2013 Thousands of free guides · Tech replies within 72h
Home Air Conditioning · Troubleshooting

Senville AC Split System Error Codes

Senville Air Conditioner Mini Split Unit Fault Codes. When error codes appear on the Senville AC unit, this tells the user there is a problem with the Senville AC unit. The error code that is displayed will tell you the problem that is occurring with the unit.

Senville Split System Air Conditioner Error Codes – TroubleshootingSenville Split System Air Conditioner Error Codes – Troubleshooting

Knowing what the error code means will help you understand and troubleshoot the part that needs to be repaired, cleaned, fixed, or replaced. You can then clean, fix, or replace the part yourself therefore saving money. NOTE: The below error codes are listed separately for the indoor unit and the outdoor unit.

SENVILLE AC INDOOR UNIT ERROR CODES

Senville Indoor AC unitSenville Indoor AC unit

Senville Mini Split Error Code (Indoor Unit) E0

Senville Error Code Definition: EEPROM parameter error

Senville Mini Split Error Code (Indoor Unit) E1

Senville Error Code Definition: Indoor / outdoor communication protection error


Senville mini split E1 error code fix

Had a power outage and inside unit began displaying an E1 error code.
Turned off the electric breaker to unit for 2 minutes.
After restoring power the unit began to function properly.

Senville Mini Split Error Code (Indoor Unit) E2

Senville Error Code Definition: Zero crossing signal error

Senville Mini Split Error Code (Indoor Unit) E3

Senville Error Code Definition: Indoor fan speed no control error

Senville Mini Split Error Code (Indoor Unit) E5

Senville Error Code Definition: Open or short circuit of outdoor temperature sensor or outdoor unit OR EEPROM parameter error

Senville Mini Split Error Code (Indoor Unit) E6

Senville Error Code Definition: Open or short circuit of room or evaporator temperature sensor error

Senville Mini Split Error Code (Indoor Unit) E7

Senville Error Code Definition: Outdoor fan speed out of control error

Senville Mini Split Error Code (Indoor Unit) P0

Senville Error Code Definition: IBM malfunction or IGBT over strong current protection error

Senville Mini Split Error Code (Indoor Unit) P1

Senville Error Code Definition: Over voltage or too low voltage protection error

Senville Mini Split Error Code (Indoor Unit) P2

Senville Error Code Definition: Temperature protection of compressor top error

Senville Mini Split Error Code (Indoor Unit) P4

Senville Error Code Definition: Inverter compressor drive error

Senville Mini Split AC Error Code Chart - Indoor UnitSenville Mini Split AC Error Code Chart – Indoor Unit

 

SENVILLE AC OUTDOOR UNIT ERROR CODES

Senville Outdoor AC UnitSenville Outdoor AC Unit

PLEASE NOTE: On the outdoor unit Board or PCB there are 2 LED lights to indicate error codes. One green LED and one red LED. You can understand what the error code is by the indication of the 2 LED lights.

Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON / LED5 RED ON

Senville Error Code Definition: Over voltage or too low voltage protection

Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON / LED5 RED OFF

Senville Error Code Definition: Standby mode

Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON

Senville Error Code Definition: Over voltage or too low voltage protection

Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN OFF / LED5 RED ON

Senville Error Code Definition: Normal operation

Senville Mini Split Error Code (Outdoor Unit) LED5 RED OFF

Senville Error Code Definition: IBM malfunction or IGBT over-strong current protection

Senville Mini Split Error Code (Outdoor Unit) Multiple LED Light Differences Will Display – Check Indoor Unit Error Code
Senville Error Code Definition: Inverter compressor drive error

Senville Mini Split AC Error Code LED Green Red Chart - Outdoor UnitSenville Mini Split AC Error Code LED Green Red Chart – Outdoor Unit

 

Senville Mini Split AC Error Code Troubleshooting Flowcharts are below…

Senville Mini Split AC Communication Error Troubleshooting FlowchartSenville Mini Split AC Communication Error Troubleshooting Flowchart

 

Senville Mini Split AC EEPROM Error Troubleshooting FlowchartSenville Mini Split AC EEPROM Error Troubleshooting Flowchart

 

Senville Mini Split AC Fan Speed Error Troubleshooting FlowchartSenville Mini Split AC Fan Speed Error Troubleshooting Flowchart

 

Senville Mini Split AC High Temperature Protection of Compressor Troubleshooting FlowchartSenville Mini Split AC High Temperature Protection of Compressor Troubleshooting Flowchart

 

Senville Mini Split AC Inverter Compressor Drive Error Troubleshooting FlowchartSenville Mini Split AC Inverter Compressor Drive Error Troubleshooting Flowchart

 

Senville Mini Split AC Over Voltage Low Voltage Error Troubleshooting FlowchartSenville Mini Split AC Over Voltage Low Voltage Error Troubleshooting Flowchart

 

Senville Mini Split AC Strong Current Protection Troubleshooting FlowchartSenville Mini Split AC Strong Current Protection Troubleshooting Flowchart

 

Senville Mini Split AC Temperature Sensor Error Troubleshooting FlowchartSenville Mini Split AC Temperature Sensor Error Troubleshooting Flowchart

 

Senville Mini Split AC Zero Crossing Detection Error TroubleshootingSenville Mini Split AC Zero Crossing Detection Error Troubleshooting

 

Below are wiring diagrams for the Senville Mini Split indoor AC unit and the outdoor AC unit if needed…

Senville Mini Split AC Indoor Unit Wiring DiagramSenville Mini Split AC Indoor Unit Wiring Diagram

 

 

Senville Mini Split AC Outdoor Unit Wiring DiagramSenville Mini Split AC Outdoor Unit Wiring Diagram

 

SENVILLE AIR CONDITIONER DC INVERTER MANUAL
Senville Mini Split AC Service Manual PDF

These error codes and troubleshooting charts apply to the following Senville Mini Split Indoor Model Numbers:
MS9A-09HRDN1-MP0W
MS9A-9HRDN1-BQ0W
MS9A-9CRDN1-BS0W
MS9A-9HRDN1-BS0W
MS9A-12HRDN1-MP0W
MS9A-12CRDN1-BS0W
MS9A-12HRDN1-BS0W
MS9A-12CRDN1-MS0W
MS9A-12HRDN1-MS0W
MS9A-12HRDN1-BS0W
MS9A-18HRDN1-MP0W
MS9A-18CRDN1-MS0W
MS9A-18HRDN1-MS0W
MS9A-24HRDN1-MP0W
MS9A-24CRDN1-MP0W
MS9A-24HRDN1-MS0W

These error codes and troubleshooting charts apply to the following Senville Mini Split Outdoor Model Numbers:
MOC-09HDN1-MP0W
MOC-9CFN1-BS0W
MOC-9HRFN1-BS0W
MOC-09HFN1-BQ0W
MOC-12HDN1-MP0W
MOC-12CFN1-BS0W
MOC-12CRDN1-MS0W
MOC-12HRFN1-BS0W
MOC-12HRFN1-MS0W
MOC-12HFN1-BS0W
MOF-18HDN1-MP0W
MOF-18CRFN1-MS0W
MOF-18HRFN1-MS0W
MOF-24HDN1-MP0W
MOF-24CDN1-MP0W
MOG-24HDN1-MP0W
MOG-24HDN1-MS0W

Senville technical support (LETO and AURA series)

Senville Parts and Accessories

Need help? Please leave your question below and we will be happy to assist you in fixing your Senville AC unit.

Keith Schneerer

Written by Keith Schneerer

Certified Appliance Tech · Founder, RemoveAndReplace.com

Keith has spent 30+ years repairing machines, starting as a military mechanic and later maintaining food processing equipment before moving into appliance repair. He founded RemoveAndReplace.com to share field-tested repair advice.

More about Keith →

17 thoughts on “Senville AC Split System Error Codes”

  1. Most often the issues are from poor installation practices. It pays to hire a professional. In many cases extra refrigerant is required to compensate for additional length of the refrigerant lines. This needs to be done in the field properly and weighed in. I have installed multiple systems and no issues yet. My customers have been more than satisfied. Great equipment at a great price!

  2. I had the Senville 36k BTU compressor with 4 – 9k BTU wall units installed around 14 months ago. Everything has worked great until today. Two of the wall units (farthest from the compressor) turn On for around 5 seconds, the display shows temperature, then the unit shuts Off. The display then shows 2 dashes (- -). I looked through the manual and it says nothing about the dashes. HELP !

  3. I’m having the same issue. Just installed a SENA-30HF/D 28,000 BTU dual zone unit and I’m getting a P6 code as well. I confirmed no leaks prior to releasing coolant so don’t believe leaks are the issue.

    The unit turned on for a bit yesterday but I noticed frosted lines by the low pressure valve so I shut it off. Tried testing it today and that’s when I got the P6 code. I also tried testing the pressure in the lines today and I don’t seem to be getting any pressure at all.

    Wondering why the unit would need additional coolant if it’s supposed to come pre-charged.

    Any help would be appreciated.

  4. ALLEN VETTER - DIY Repair Assistant

    Raul Gutierrez,
    Senville 4 zone 36000 btu – error code P6
    P6 error code on Senville AC means the outside unit is not cooling and needs more refrigerant.
    Possibly one of the valves is not open all the way and not sending refrigerant to the whole unit.
    It’s most common when it’s super hot outside and the unit isn’t able to cool properly.
    -RR

  5. I just installed a Senville 4 zone 36000 btu and did not work.
    It gives me an error code P6, what can I do to fix it.

Leave a Comment

Your email address will not be published. Required fields are marked *