Senville AC Split System Error Codes

Senville Air Conditioner Mini Split Unit Fault Codes. When error codes appear on the Senville AC unit, this tells the user there is a problem with the Senville AC unit. The error code that is displayed will tell you the problem that is occurring with the unit.

Senville Split System Air Conditioner Error Codes – TroubleshootingSenville Split System Air Conditioner Error Codes – Troubleshooting

Knowing what the error code means will help you understand and troubleshoot the part that needs to be repaired, cleaned, fixed, or replaced. You can then clean, fix, or replace the part yourself therefore saving money. NOTE: The below error codes are listed separately for the indoor unit and the outdoor unit.

SENVILLE AC INDOOR UNIT ERROR CODES

Senville Indoor AC unitSenville Indoor AC unit

Senville Mini Split Error Code (Indoor Unit) E0

Senville Error Code Definition: EEPROM parameter error

Senville Mini Split Error Code (Indoor Unit) E1

Senville Error Code Definition: Indoor / outdoor communication protection error


Senville mini split E1 error code fix

Had a power outage and inside unit began displaying an E1 error code.
Turned off the electric breaker to unit for 2 minutes.
After restoring power the unit began to function properly.

Senville Mini Split Error Code (Indoor Unit) E2

Senville Error Code Definition: Zero crossing signal error

Senville Mini Split Error Code (Indoor Unit) E3

Senville Error Code Definition: Indoor fan speed no control error

Senville Mini Split Error Code (Indoor Unit) E5

Senville Error Code Definition: Open or short circuit of outdoor temperature sensor or outdoor unit OR EEPROM parameter error

Senville Mini Split Error Code (Indoor Unit) E6

Senville Error Code Definition: Open or short circuit of room or evaporator temperature sensor error

Senville Mini Split Error Code (Indoor Unit) E7

Senville Error Code Definition: Outdoor fan speed out of control error

Senville Mini Split Error Code (Indoor Unit) P0

Senville Error Code Definition: IBM malfunction or IGBT over strong current protection error

Senville Mini Split Error Code (Indoor Unit) P1

Senville Error Code Definition: Over voltage or too low voltage protection error

Senville Mini Split Error Code (Indoor Unit) P2

Senville Error Code Definition: Temperature protection of compressor top error

Senville Mini Split Error Code (Indoor Unit) P4

Senville Error Code Definition: Inverter compressor drive error

Senville Mini Split AC Error Code Chart - Indoor UnitSenville Mini Split AC Error Code Chart – Indoor Unit

 

SENVILLE AC OUTDOOR UNIT ERROR CODES

Senville Outdoor AC UnitSenville Outdoor AC Unit

PLEASE NOTE: On the outdoor unit Board or PCB there are 2 LED lights to indicate error codes. One green LED and one red LED. You can understand what the error code is by the indication of the 2 LED lights.

Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON / LED5 RED ON

Senville Error Code Definition: Over voltage or too low voltage protection

Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON / LED5 RED OFF

Senville Error Code Definition: Standby mode

Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON

Senville Error Code Definition: Over voltage or too low voltage protection

Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN OFF / LED5 RED ON

Senville Error Code Definition: Normal operation

Senville Mini Split Error Code (Outdoor Unit) LED5 RED OFF

Senville Error Code Definition: IBM malfunction or IGBT over-strong current protection

Senville Mini Split Error Code (Outdoor Unit) Multiple LED Light Differences Will Display – Check Indoor Unit Error Code
Senville Error Code Definition: Inverter compressor drive error

Senville Mini Split AC Error Code LED Green Red Chart - Outdoor UnitSenville Mini Split AC Error Code LED Green Red Chart – Outdoor Unit

 

Senville Mini Split AC Error Code Troubleshooting Flowcharts are below…

Senville Mini Split AC Communication Error Troubleshooting FlowchartSenville Mini Split AC Communication Error Troubleshooting Flowchart

 

Senville Mini Split AC EEPROM Error Troubleshooting FlowchartSenville Mini Split AC EEPROM Error Troubleshooting Flowchart

 

Senville Mini Split AC Fan Speed Error Troubleshooting FlowchartSenville Mini Split AC Fan Speed Error Troubleshooting Flowchart

 

Senville Mini Split AC High Temperature Protection of Compressor Troubleshooting FlowchartSenville Mini Split AC High Temperature Protection of Compressor Troubleshooting Flowchart

 

Senville Mini Split AC Inverter Compressor Drive Error Troubleshooting FlowchartSenville Mini Split AC Inverter Compressor Drive Error Troubleshooting Flowchart

 

Senville Mini Split AC Over Voltage Low Voltage Error Troubleshooting FlowchartSenville Mini Split AC Over Voltage Low Voltage Error Troubleshooting Flowchart

 

Senville Mini Split AC Strong Current Protection Troubleshooting FlowchartSenville Mini Split AC Strong Current Protection Troubleshooting Flowchart

 

Senville Mini Split AC Temperature Sensor Error Troubleshooting FlowchartSenville Mini Split AC Temperature Sensor Error Troubleshooting Flowchart

 

Senville Mini Split AC Zero Crossing Detection Error TroubleshootingSenville Mini Split AC Zero Crossing Detection Error Troubleshooting

 

Below are wiring diagrams for the Senville Mini Split indoor AC unit and the outdoor AC unit if needed…

Senville Mini Split AC Indoor Unit Wiring DiagramSenville Mini Split AC Indoor Unit Wiring Diagram

 

 

Senville Mini Split AC Outdoor Unit Wiring DiagramSenville Mini Split AC Outdoor Unit Wiring Diagram

 

SENVILLE AIR CONDITIONER DC INVERTER MANUAL
Senville Mini Split AC Service Manual PDF

These error codes and troubleshooting charts apply to the following Senville Mini Split Indoor Model Numbers:
MS9A-09HRDN1-MP0W
MS9A-9HRDN1-BQ0W
MS9A-9CRDN1-BS0W
MS9A-9HRDN1-BS0W
MS9A-12HRDN1-MP0W
MS9A-12CRDN1-BS0W
MS9A-12HRDN1-BS0W
MS9A-12CRDN1-MS0W
MS9A-12HRDN1-MS0W
MS9A-12HRDN1-BS0W
MS9A-18HRDN1-MP0W
MS9A-18CRDN1-MS0W
MS9A-18HRDN1-MS0W
MS9A-24HRDN1-MP0W
MS9A-24CRDN1-MP0W
MS9A-24HRDN1-MS0W

These error codes and troubleshooting charts apply to the following Senville Mini Split Outdoor Model Numbers:
MOC-09HDN1-MP0W
MOC-9CFN1-BS0W
MOC-9HRFN1-BS0W
MOC-09HFN1-BQ0W
MOC-12HDN1-MP0W
MOC-12CFN1-BS0W
MOC-12CRDN1-MS0W
MOC-12HRFN1-BS0W
MOC-12HRFN1-MS0W
MOC-12HFN1-BS0W
MOF-18HDN1-MP0W
MOF-18CRFN1-MS0W
MOF-18HRFN1-MS0W
MOF-24HDN1-MP0W
MOF-24CDN1-MP0W
MOG-24HDN1-MP0W
MOG-24HDN1-MS0W

Senville technical support (LETO and AURA series)

Senville Parts and Accessories

Need help? Please leave your question below and we will be happy to assist you in fixing your Senville AC unit.

Keith Schneerer

Written by Keith Schneerer

Certified Appliance Tech · Founder, RemoveAndReplace.com

Keith has spent 30+ years repairing machines, starting as a military mechanic and later maintaining food processing equipment before moving into appliance repair. He founded RemoveAndReplace.com to share field-tested repair advice.

More about Keith →

17 thoughts on “Senville AC Split System Error Codes”

  1. Michael Miller

    Senville mini split was showing P4 in the winter and not making heat. And now it the summer it says code EC? Any ideas ?

  2. Thomas A. Tolve

    Senville heat pump Mod.# SENL09CD/IZ indoor unit with Mod # SENL09CD/OZ outdoor unit. 115 volt.
    When call for cooling is made the outdoor unit dose not operate ( no condenser fan motor or compressor is operational.
    And at the same time the indoor blower operates at a very low speed regardless to remote control selection and no indication error code light is illuminated.

  3. timothy donald curtis

    Senville 24CD AC unit, new install, set it on 72 degrees its 68 degrees in our home and still running set on cool.

  4. Were you able to resolve your P6 code? We are getting the same and not certain what went wrong – bought precharged 28,000 BTU tri-zone Senville Aura with 25 ft linesets, followed installation instructions, tested pressure and vacuumed lines. Units ran for 30 mins before throwing a P1 code, turned off and back on; ran for 1 hr before throwing a P6 code. Now, every time the units are turned on all indoor units throw a P6 after approximately 3 minutes. Tech will be coming back tomorrow to check it out, but I’m wondering if there’s something simple we overlooked.

  5. Just install new Senville dual zone mini split vacuumed lines, opened valves after powering on immediately receive P6 code on both heads, double checked for leaks, all good there. Powered off at the breaker for 15 min still getting P6 code. Contacted heating/ac company say not enough refrigerant according to e code on compressor

  6. William Browning

    Purchased and had my Senville SENL/09CD/220/1X install in Aug 2020. No issues until about 1 month ago. I received a P4 code. Came on went off. Just happened this morning (12/22/2020), came on went off. Heats/Cools fine. Please advise.