Senville Air Conditioner Mini Split Unit Fault Codes. When error codes appear on the Senville AC unit, this tells the user there is a problem with the Senville AC unit. The error code that is displayed will tell you the problem that is occurring with the unit.
Senville Split System Air Conditioner Error Codes – Troubleshooting
Knowing what the error code means will help you understand and troubleshoot the part that needs to be repaired, cleaned, fixed, or replaced. You can then clean, fix, or replace the part yourself therefore saving money. NOTE: The below error codes are listed separately for the indoor unit and the outdoor unit.
SENVILLE AC INDOOR UNIT ERROR CODES
Senville Mini Split Error Code (Indoor Unit) E0
Senville Error Code Definition: EEPROM parameter error
Senville Mini Split Error Code (Indoor Unit) E1
Senville Error Code Definition: Indoor / outdoor communication protection error
Senville mini split E1 error code fix
Had a power outage and inside unit began displaying an E1 error code.
Turned off the electric breaker to unit for 2 minutes.
After restoring power the unit began to function properly.
Senville Mini Split Error Code (Indoor Unit) E2
Senville Error Code Definition: Zero crossing signal error
Senville Mini Split Error Code (Indoor Unit) E3
Senville Error Code Definition: Indoor fan speed no control error
Senville Mini Split Error Code (Indoor Unit) E5
Senville Error Code Definition: Open or short circuit of outdoor temperature sensor or outdoor unit OR EEPROM parameter error
Senville Mini Split Error Code (Indoor Unit) E6
Senville Error Code Definition: Open or short circuit of room or evaporator temperature sensor error
Senville Mini Split Error Code (Indoor Unit) E7
Senville Error Code Definition: Outdoor fan speed out of control error
Senville Mini Split Error Code (Indoor Unit) P0
Senville Error Code Definition: IBM malfunction or IGBT over strong current protection error
Senville Mini Split Error Code (Indoor Unit) P1
Senville Error Code Definition: Over voltage or too low voltage protection error
Senville Mini Split Error Code (Indoor Unit) P2
Senville Error Code Definition: Temperature protection of compressor top error
Senville Mini Split Error Code (Indoor Unit) P4
Senville Error Code Definition: Inverter compressor drive error
Senville Mini Split AC Error Code Chart – Indoor Unit
SENVILLE AC OUTDOOR UNIT ERROR CODES
PLEASE NOTE: On the outdoor unit Board or PCB there are 2 LED lights to indicate error codes. One green LED and one red LED. You can understand what the error code is by the indication of the 2 LED lights.
Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON / LED5 RED ON
Senville Error Code Definition: Over voltage or too low voltage protection
Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON / LED5 RED OFF
Senville Error Code Definition: Standby mode
Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN ON
Senville Error Code Definition: Over voltage or too low voltage protection
Senville Mini Split Error Code (Outdoor Unit) LED6 GREEN OFF / LED5 RED ON
Senville Error Code Definition: Normal operation
Senville Mini Split Error Code (Outdoor Unit) LED5 RED OFF
Senville Error Code Definition: IBM malfunction or IGBT over-strong current protection
Senville Mini Split Error Code (Outdoor Unit) Multiple LED Light Differences Will Display – Check Indoor Unit Error Code
Senville Error Code Definition: Inverter compressor drive error
Senville Mini Split AC Error Code LED Green Red Chart – Outdoor Unit
Senville Mini Split AC Error Code Troubleshooting Flowcharts are below…
Senville Mini Split AC Communication Error Troubleshooting Flowchart
Senville Mini Split AC EEPROM Error Troubleshooting Flowchart
Senville Mini Split AC Fan Speed Error Troubleshooting Flowchart
Senville Mini Split AC High Temperature Protection of Compressor Troubleshooting Flowchart
Senville Mini Split AC Inverter Compressor Drive Error Troubleshooting Flowchart
Senville Mini Split AC Over Voltage Low Voltage Error Troubleshooting Flowchart
Senville Mini Split AC Strong Current Protection Troubleshooting Flowchart
Senville Mini Split AC Temperature Sensor Error Troubleshooting Flowchart
Senville Mini Split AC Zero Crossing Detection Error Troubleshooting
Below are wiring diagrams for the Senville Mini Split indoor AC unit and the outdoor AC unit if needed…
Senville Mini Split AC Indoor Unit Wiring Diagram
Senville Mini Split AC Outdoor Unit Wiring Diagram
SENVILLE AIR CONDITIONER DC INVERTER MANUAL
Senville Mini Split AC Service Manual PDF
These error codes and troubleshooting charts apply to the following Senville Mini Split Indoor Model Numbers:
MS9A-09HRDN1-MP0W
MS9A-9HRDN1-BQ0W
MS9A-9CRDN1-BS0W
MS9A-9HRDN1-BS0W
MS9A-12HRDN1-MP0W
MS9A-12CRDN1-BS0W
MS9A-12HRDN1-BS0W
MS9A-12CRDN1-MS0W
MS9A-12HRDN1-MS0W
MS9A-12HRDN1-BS0W
MS9A-18HRDN1-MP0W
MS9A-18CRDN1-MS0W
MS9A-18HRDN1-MS0W
MS9A-24HRDN1-MP0W
MS9A-24CRDN1-MP0W
MS9A-24HRDN1-MS0W
These error codes and troubleshooting charts apply to the following Senville Mini Split Outdoor Model Numbers:
MOC-09HDN1-MP0W
MOC-9CFN1-BS0W
MOC-9HRFN1-BS0W
MOC-09HFN1-BQ0W
MOC-12HDN1-MP0W
MOC-12CFN1-BS0W
MOC-12CRDN1-MS0W
MOC-12HRFN1-BS0W
MOC-12HRFN1-MS0W
MOC-12HFN1-BS0W
MOF-18HDN1-MP0W
MOF-18CRFN1-MS0W
MOF-18HRFN1-MS0W
MOF-24HDN1-MP0W
MOF-24CDN1-MP0W
MOG-24HDN1-MP0W
MOG-24HDN1-MS0W
Senville technical support (LETO and AURA series)
Senville Parts and Accessories
Need help? Please leave your question below and we will be happy to assist you in fixing your Senville AC unit.


James,
Your Senville mini-split system showing a (df) code usually means it’s trying to defrost itself, thinking there’s ice even if you can’t see any. The double dashes (–), which aren’t explained in the manual, might mean there’s a problem with how the inside and outside parts talk to each other or a small glitch that needs resetting. You can try turning the whole system off and on again to see if it fixes the issue, make sure all the indoor units are set to the same mode to avoid conflicts, and check that all wires are connected properly and not damaged.
-RR
I have the Senville 36k BTU compressor with 3 – 9k BTU wall units installed.
Everything has worked great until but sometimes I get the (df) code and have no reason why because there is no evidence of any icing on the outside compressor unit.
Also all 3 of the wall units will sometimes display the 2 dashes (- -).
I’ve looked through the manual and it says nothing about the dashes. HELP !
Michael Miller,
An EC error code on a Senville mini split will happen when the unit sees or senses a refrigerant leak.
This can be from a faulty temperature sensor, leakage or blockage in the lines, or a malfunctioning indoor main board.
-RR